ControlLogix

|
- 128,000 digital (any mix) 2
|
- Local I/O
- EtherNet/IP I/O
- ControlNet I/O
- DeviceNet I/O
- Universal Remote I/O
|
- 160K bytes
- 672K bytes
- 1M bytes
- 2M bytes
|
- EtherNet
- ControlNet
- DeviceNet
- DH-485
- RS-232-C (DF1/DH-485)
- Universal Remote I/O
|
FlexLogix

|
|
- Local I/O
- Extended Local I/O
- ControlNet I/O
|
|
- EtherNet/IP
- ControlNet
- DeviceNet
- RS-232-C
- Extended Local I/O
|
CompactLogix

|
|
|
|
- EtherNet/IP 4
- DeviceNet 4
- RS-232-C
|
SoftLogix 5800

|
|
- ControlNet I/O 3
- DeviceNet I/O 3
- Universal Remote I/O 3
|
|
- Ethernet
- ControlNet
- Devicenet
- DH+
- Universal Remote I/O
|
SoftLogix 5 Controller

|
|
- ControlNet I/O
- Devicenet I/O
- Universal Remote I/O (via third-party communication cards)
- Third-party I/O
|
- 8M byte program size
- 4096 program files
- 4096 data table files
- 4096 elements per data table file
- 4096 sequential function chart (sfc sub charts)
|
- Ethernet
- ControlNet
- DeviceNet
- DH+
- Universal Remote I/O
- Serial
- Third-party networks
|
PLC -5/1771

|
- 512 thru 3072 (any mix) 2
|
- Processor-resident local I/O
- Extended local I/O
- DeviceNet I/O 3
- ControlNet I/O
|
- 6K thru 100k words
- protected
|
- EtherNet/IP 5
- ControlNet
- DeviceNet 4
- DH+
- RS-232-C
- RS-422-A
- RS-423-A
- Universal Remote I/O
|
SLC 500/1746

|
|
- Fixed hardware digital I/O plus 2 local I/O modules
- 30 local I/O modules
- ControlNet I/O
- DeviceNet I/O 3
|
- 1K instructions
- 1K thru 4K instructions
- 4K instructions
- 8K words
- 16K words
|
- EtherNet/IP
- ControlNet 4
- DeviceNet 4
- DH+
- DH-485
- RS-232-C
- Universal Remote I/O 3
|
MicroLogix



|
MicroLogix 1000
|
- Fixed digital I/O
- Fixed analog I/O
|
|
- DeviceNet 4
- EtherNet/IP 4
- DH-485 4
- RS-232-C
|
MicroLogix 1200
|
- Processor-resident local I/O
- Extended local I/O
|
- 4K words program
- 2K words data
|
- DeviceNet 4
- EtherNet/IP 4
- DH-485 4
- RS-232-C
|
MicroLogix 1500
|
- Embedded local I/O
- Extended local I/O
|
|
- DeviceNet 4
- EtherNet/IP 4
- DH-485 4
- RS-232-C
|
Pico Controller

|
|
- Processor-resident local I/O
|
- 164 instructions for 12 I/O controllers
- 484 instructions for 18 I/O controllers
|
|
Guard PLC Controllers  |
- 30 digital or
- 144 digital inputs, 96 digital outputs or 48 analog inputs, or 48 analog outputs
|
|
- 500K bytes of applicaition program memory
- 500K bytes of application data memory
|
- RS-232-C
- EtherNet for programming and configuration
|
- This includes Universal Remote I/O and DeviceNet I/O.
- This does not include DeviceNet I/O.
- This type of I/O in this control system requires a seperate I/O scanner installed in an I/O module slot.
- These are not on-board ports. They are available only thru an interface.
- Only some have on-board EtherNet/IP ports. But all have the capability to have an EtherNet/IP port added thru an interface.
|